Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
ACS Sens ; 8(5): 1960-1970, 2023 05 26.
Article in English | MEDLINE | ID: covidwho-2306620

ABSTRACT

Rapid and accurate detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is one of the most effective measures to control the coronavirus disease 2019 (COVID-19) pandemic. However, there is still lack of an ideal detection platform capable of high sample throughput, portability, and multiplicity. Herein, by combining Hive-Chip (capillary microarray) and reverse transcriptional loop-mediated isothermal amplification (RT-LAMP), we developed an iPad-controlled, high-throughput (48 samples at one run), portable (smaller than a backpack), multiplex (monitoring 8 gene fragments in one reaction), and real-time detection platform for SARS-CoV-2 detection. This platform is composed of a portable Hive-Chip device (HiCube; 32.7 × 29.7 × 20 cm, 5 kg), custom-designed software, and optimized Hive-Chips. RT-LAMP primers targeting seven SARS-CoV-2 genes (S, E, M, N, ORF1ab, ORF3a, and ORF7a) and one positive control (human RNase P) were designed and prefixed in the Hive-Chip. On-chip RT-LAMP showed that the limit of detection (LOD) of SARS-CoV-2 synthetic RNAs is 1 copy/µL, and there is no cross-reaction among different target genes. The platform was validated by 100 clinical samples of SARS-CoV-2, and the results were highly consistent with those of the traditional real-time PCR assay. In addition, on-chip detection of 6 other respiratory pathogens showed no cross-reactivity. Overall, our platform has great potential for fast, accurate, and on-site detection of SARS-CoV-2.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , SARS-CoV-2/genetics , COVID-19/diagnosis , COVID-19 Testing , Limit of Detection , RNA, Viral/genetics , RNA, Viral/analysis
2.
Biosensors (Basel) ; 12(1)2021 Dec 26.
Article in English | MEDLINE | ID: covidwho-2287828

ABSTRACT

Coronavirus disease 2019 (COVID-19) caused by the SARS-CoV-2 virus has led to a global pandemic with a high spread rate and pathogenicity. Thus, with limited testing solutions, it is imperative to develop early-stage diagnostics for rapid and accurate detection of SARS-CoV-2 to contain the rapid transmission of the ongoing COVID-19 pandemic. In this regard, there remains little knowledge about the integration of the CRISPR collateral cleavage mechanism in the lateral flow assay and fluorophotometer. In the current study, we demonstrate a CRISPR/Cas12a-based collateral cleavage method for COVID-19 diagnosis using the Cas12a/crRNA complex for target recognition, reverse transcription loop-mediated isothermal amplification (RT-LAMP) for sensitivity enhancement, and a novel DNA capture probe-based lateral flow strip (LFS) or real-time fluorescence detector as the parallel system readout facility, termed CRICOLAP. Our novel approach uses a customized reporter that hybridizes an optimized complementary capture probe fixed at the test line for naked-eye result readout. The CRICOLAP system achieved ultra-sensitivity of 1 copy/µL in ~32 min by portable real-time fluorescence detection and ~60 min by LFS. Furthermore, CRICOLAP validation using 60 clinical nasopharyngeal samples previously verified with a commercial RT-PCR kit showed 97.5% and 100% sensitivity for S and N genes, respectively, and 100% specificity for both genes of SARS-CoV-2. CRICOLAP advances the CRISPR/Cas12a collateral cleavage result readout in the lateral flow assay and fluorophotometer, and it can be an alternative method for the decentralized field-deployable diagnosis of COVID-19 in remote and limited-resource locations.


Subject(s)
COVID-19 Testing , COVID-19 , CRISPR-Cas Systems , COVID-19/diagnosis , Humans , Molecular Diagnostic Techniques , Nucleic Acid Amplification Techniques , RNA, Viral , SARS-CoV-2 , Sensitivity and Specificity
3.
Anal Chim Acta ; 1200: 339590, 2022 Apr 01.
Article in English | MEDLINE | ID: covidwho-1682826

ABSTRACT

The global public health crisis and economic losses resulting from the current novel coronavirus disease (COVID-19) pandemic have been dire. The most used real-time reverse transcription polymerase chain reaction (RT-PCR) method needs expensive equipment, technical expertise, and a long turnaround time. Therefore, there is a need for a rapid, accurate, and alternative technique of diagnosis that is deployable at resource-poor settings like point-of-care. This study combines heat deactivation and a novel mechanical lysis method by bead beating for quick and simple sample preparation. Then, using an optimized reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay to target genes encoding the open reading frame 8 (ORF8), spike and nucleocapsid proteins of the novel coronavirus, SARS-CoV-2. The test results can be read simultaneously in fluorometric and colorimetric readouts within 40 min from sample collection. We also calibrated a template transfer tool to simplify sample addition into LAMP reactions when pipetting skills are needed. Most importantly, validation of the direct RT-LAMP system based on multiplexing primers S1:ORF8 in a ratio (1:0.8) using 143 patients' nasopharyngeal swab samples showed a diagnostic performance of 99.30% accuracy, with 98.81% sensitivity and 100% selectivity, compared to commercial RT-PCR kits. Since our workflow does not rely on RNA extraction and purification, the time-to-result is two times faster than other workflows with FDA emergency use authorization. Considering all its strengths: speed, simplicity, accuracy and extraction-free, the system can be useful for optimal point-of-care testing of COVID-19.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , COVID-19 Testing , Humans , Molecular Diagnostic Techniques , Nucleic Acid Amplification Techniques/methods , Point-of-Care Systems , RNA, Viral/analysis , RNA, Viral/genetics , Reverse Transcriptase Polymerase Chain Reaction , Reverse Transcription , SARS-CoV-2/genetics , Sensitivity and Specificity
4.
Expert Rev Mol Diagn ; 21(1): 119-129, 2021 01.
Article in English | MEDLINE | ID: covidwho-1003446

ABSTRACT

Introduction: With the ongoing SARS-CoV-2 pandemic, different articles have been published highlighting the superiority of droplet digital PCR (ddPCR) over the gold-standard reverse transcription PCR (RT-PCR) in SARS-CoV-2 detection. However, few studies have been reported on developing multiplex ddPCR assays for SARS-CoV-2 detection and their performance. This study shows steps on how to develop different ddPCR SAR-CoV-2 assays including higher order multiplex assays for SARS-CoV-2 detection and antiviral screening.Methods: Using multiple primer/probe sets, we developed, optimized, and analyzed the performance of simplex (1 target), duplex (2 targets), triplex probe mix (3 targets), and quadruplex (4 targets) SARS-CoV-2 ddPCR assays based on a two-color ddPCR detection system.Results: Results showed that the quadruplex assay had similar limits of detection and accuracy to the lower multiplex assays. Analyzing 94 clinical samples demonstrated that the ddPCR triplex probe mix assay had better sensitivity than the RT-qPCR assay. Additionally, the ddPCR multiplex assay showed that remdesivir could inhibit the growth of SARS-CoV-2 in vitro while another testing drug could not.Conclusion: Our research shows that developing multiplex ddPCR assays is possible by combing probe mix and amplitude-based multiplexing, which will help in developing multiplexed ddPCR assays for different SARS-CoV-2 applications.


Subject(s)
COVID-19 Nucleic Acid Testing , COVID-19/diagnosis , Multiplex Polymerase Chain Reaction/methods , SARS-CoV-2/isolation & purification , Antiviral Agents/pharmacology , DNA Primers/genetics , False Positive Reactions , Humans , Limit of Detection , Pandemics , RNA, Viral/isolation & purification , Real-Time Polymerase Chain Reaction/methods , Reproducibility of Results , Sensitivity and Specificity , Temperature , Viral Load/methods
SELECTION OF CITATIONS
SEARCH DETAIL